zero water pressure in the boiler






When the water rises in the heating system to a physical law also tends to raise the water pressure. If the expansion tank

is not loading (laundry or just deflated) when the pressure reaches about 2.5 Ate ago intervene safety valve calibrated at 3 Ate boiler

that drains water, lowering the pressure even down to zero . For the repair check the expansion tank is loaded (note the verification should be performed to gauge the value of zero. Load the expansion tank with a compressor to about 0.75 ate (if the facility is all on one floor), refilled the boiler. Usually when the expansion tank is not punctured, the inlet valve is heard out of the air, but if only water is released most likely laundry.


If you want to buy these products, click below.

My status
Get Skype and call me for free.


only from Monday to Friday from 08:00 to 12:00 and from 14:00 to 18:00





Or contact me at my e.mail



Reference codes:
expansion tank 8716142500 0
safety relief valve
8716142404 0





Tuesday, November 6, 2007

Car Auctions In Canton Ohio

Boiler Wall: Novastar 24 AE / KE

With time here are some actions that I had to make up for this product.
The electronic card is able to make a diagnosis of very mild failure.
understanding of the problem occurs intermittently by the flashing light on the block, on the control panel
example of failure to NTC

opening the hot water faucet flashes of light on the lock button 4 times per second (very fast)

Replace NTC shown here under



The same type of block you can have in heating mode, when the left knob on the control panel is in heating mode, and the thermostat closes the contact (thermostat in heating mode active).
If the sensor is faulty we have shown here under the flashing light on the key block 4 times per second (very fast).




happens that the pressure also tends to increase from cold to reach the 3 atmospheres
probably after checking that (the faucet is not dead) was washing the secondary heat exchanger.


If you want to buy these products, click below.

My status
Get Skype and call me for free.


only from Monday to Friday 08:00 to 12:00 and 14:00 to 18:00





Or contact me at my e.mail



Reference codes: NTC sensor
87161423840 87161429000
exchanger secondary